ASTR 340 · Lecture 03

Plate Scale, Field of View, and Focal-Plane Geometry

Converting an angle on the sky into a distance on a detector

Learning Goals

  1. Derive the plate-scale relation linking angular separation on the sky to physical separation at the focal plane.
  2. Compute the plate scale and pixel scale of a real telescope-plus-instrument combination.
  3. Apply the Nyquist sampling criterion to determine whether a given pixel size adequately samples a telescope’s diffraction-limited or seeing-limited image.

Reading anchor: OpenStax Astronomy 2e (local extracted reference copy: references/openstax-astronomy-2e-extracted.txt) covers observational instrumentation only descriptively (Chapter 6, astronomical instruments); this course derives the optics, detector, and error-budget physics explicitly, well beyond that introductory treatment.

Why This Matters

Lecture 02 fixed how sharp an image a telescope can in principle deliver. This lecture answers the practical question every instrument designer must solve next: how large, in millimeters, does that sharp image actually appear at the focal plane, and how small must a detector’s pixels be to record it without throwing resolution away?

Opening Phenomenon

The Dark Energy Camera (DECam), a 570-megapixel imager built from 62 CCDs on the 4 m Blanco telescope, uses 15 μm pixels and a 11.28 m effective focal length to achieve a 0.274 arcsec/pixel image scale -- a deliberate engineering choice, not an accident, that this lecture’s plate-scale relation shows was necessary to properly sample the site’s seeing disk.

First question: what here is directly observed or a published instrument specification, and what follows only once a physical law is derived and applied?

Terms for This Lecture

plate scale

Definition: Plate scale denotes the physical quantity, process, or instrument component captured by this lecture-specific statement: Multiplying the plate scale by a detector’s physical pixel size (in mm) gives the pixel scale in arcsec/pixel -- the practical number that determines both a camera’s field of view (pixel scale × detector width) and its ability to resolve fine structure.

Why it matters here: Lecture 02 fixed how sharp an image a telescope can in principle deliver. This lecture answers the practical question every instrument designer must solve next: how large, in millimeters, does that sharp image actually appear at the focal plane, and how small must a detector’s pixels be to record it without throwing resolution...

Relationships: It is used with pixel scale to interpret the lecture model. The quantitative connection is the working relation \(s = \dfrac{206265^{\prime\prime}}{f\,[\mathrm{mm}]}, \qquad \text{pixel scale} = s \times p\,[\mathrm{mm}], \qquad \text{Nyquist: pixel scale} \le \dfrac{\mathrm{FWHM}}{2}\).

Boundary or common confusion: Assuming a smaller pixel is always better. Undersampling wastes optical resolution, but excessively small pixels (oversampling) spread the same total signal across more pixels, each carrying its own read-noise contribution (Lecture 05), which can lower the effective signal-to-noise ratio for faint sources without any corresponding gain in usable resolution...

Evidence We Need to Explain

Derivation and Model

Quantitative Tool

\[ s = \dfrac{206265^{\prime\prime}}{f\,[\mathrm{mm}]}, \qquad \text{pixel scale} = s \times p\,[\mathrm{mm}], \qquad \text{Nyquist: pixel scale} \le \dfrac{\mathrm{FWHM}}{2} \]

Worked Example

  1. Keck plate scale from f=17.5 m: s = 206265″/(1000×17.5) = 11.787 arcsec/mm, roughly 3.29× the plate scale of HST (f=57.6 m, s=3.581 arcsec/mm) despite Keck’s much larger aperture, because plate scale depends on focal length, not aperture, alone.
  2. DECam pixel scale from its published f=11.28 m and p=15 μm pixels: pixel scale = 18.286 arcsec/mm × 0.015 mm = 0.274 arcsec/pixel, matching the camera’s own published specification.
  3. Nyquist check against Keck’s diffraction limit: half the V-band Rayleigh resolution is 6.9 milliarcsec/pixel -- far finer than DECam’s 0.274″/pixel, confirming (correctly) that DECam is designed to Nyquist-sample the site’s seeing disk, not Keck’s diffraction limit, since DECam sits on a different, seeing-limited 4 m telescope.

Visual Reasoning

Trace the reasoning chain from raw observation or instrument specification to derived physical law to inferred quantity in this lecture’s figure.

  • Which stage is directly observed or specified?
  • Which stage is the physical law or derivation step?
  • What would change if an assumption in the derivation failed?
Lecture 03: Plate Scale, Field of View, and Focal-Plane Geometrylog₁₀(effective focal length, m)log₁₀(plate scale, arcsec/mm)HST: f=57.6 m, s=3.58″/mmKeck: f=17.5 m, s=11.79″/mmVLT: f=120.0 m, s=1.72″/mmJWST: f=131.4 m, s=1.57″/mmDECam host (Blanco 4m): f=11.3 m, s=18.29″/mmPlate scale s=206265″/f[mm] falls as focal length rises: five real telescopes span more than a factor of 10 in focal length and plate scale.
Plate Scale, Field of View, and Focal-Plane Geometry: from observation to inferred quantity.

Common Misconception

Assuming a smaller pixel is always better. Undersampling wastes optical resolution, but excessively small pixels (oversampling) spread the same total signal across more pixels, each carrying its own read-noise contribution (Lecture 05), which can lower the effective signal-to-noise ratio for faint sources without any corresponding gain in usable resolution once the Nyquist criterion is already satisfied.

Active Learning Segment

Given DECam’s pixel scale and the Blanco 4 m telescope’s seeing-limited image quality (typically 0.9-1.1 arcsec FWHM at the site), estimate how many pixels sample the FWHM of a typical stellar image, and state whether this imager is undersampled, well-sampled, or oversampled relative to the Nyquist criterion.

Lab Connection

Lab 02 computes the plate scale and pixel scale for several real telescope-instrument pairs and checks each against the Nyquist criterion using the diffraction or seeing limit established in Lecture 02.

Synthesis

Plate scale converts a telescope’s focal length into a concrete number of arcseconds per millimeter at the focal plane, and the Nyquist criterion then dictates how small a detector’s pixels must be to preserve, rather than discard, the resolution the telescope optics (Lecture 02) already deliver.

References